What to do if the central air conditioner is not heating

With the arrival of winter, the heating function of central air conditioners has become the focus of attention in many homes and offices. However, many users have reported that central air conditioners have problems with not heating. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the reasons and solutions for central air conditioners not heating, and provide structured data for reference.

1. Common reasons why central air conditioners do not heat

What to do if the central air conditioner is not heating

According to recent user feedback and maintenance data, the main reasons why the central air conditioner does not heat include the following points:

ReasonProportionTypical symptoms
Filter clogged35%The air volume at the air outlet is small and the heating efficiency is low.
Insufficient refrigerant25%The heating effect is poor and the outdoor unit operates abnormally.
Four-way valve failure15%Unable to switch heating mode
Outdoor temperature is too low10%Heating capacity decreases below -5°C
Circuit or control system failure10%The display shows an error and cannot be started.
other reasons5%Including installation problems, equipment aging, etc.

2. Solution to central air conditioner not heating

In response to the above problems, we have compiled the following solutions:

Question typeSolutionOperation difficulty
Filter clogged1. Turn off the power
2. Take out the filter and clean it
3. Put it back after drying
simple
Insufficient refrigerant1. Contact a professional for testing
2. Replenish refrigerant
Professional
Four-way valve failure1. Try to restart the system
2. Contact after-sales service to replace the four-way valve
Professional
Outdoor temperature is too low1. Turn on auxiliary electric heating
2. Maintain ventilation around the outdoor unit
medium
circuit failure1. Check the power supply
2. Reset control system
3. Contact professional maintenance
Professional

3. The five issues that users are most concerned about recently

According to search platform data statistics, the central air conditioning heating issues that users are most concerned about in the past 10 days are as follows:

Rankingquestionsearch volume
1Central air conditioning is not responding12,500 times
2Central air conditioning has poor heating effect9,800 times
3Central air conditioner outdoor unit not working7,200 times
4There is a peculiar smell in the central air conditioner5,600 times
5Central air conditioning heating power consumption4,300 times

4. Professional maintenance suggestions

1.Regular maintenance:It is recommended to perform professional maintenance every year before use, including cleaning the filter, checking the refrigerant pressure, etc.

2.Temperature settings:When heating, it is recommended to set the temperature between 20-24°C. If it is too high, the efficiency will decrease.

3.Usage environment:Keep the indoor airtight to avoid heat loss; ensure there are no obstructions around the outdoor unit.

4.Emergency treatment:If there is no heating suddenly, you can first try to cut off the power and restart it. If it doesn't work, contact professional maintenance.

5.Brand differences:Different brands of central air conditioners may have different fault codes and solutions. It is recommended to consult the manual.

5. Tips for using central air conditioners in winter

1. Before heating, open the windows for ventilation for 10 minutes to refresh the indoor air.

2. Adjust the air volume to the maximum when it is first turned on, and then adjust it to the appropriate air volume after the temperature rises.

3. Use a humidifier to prevent the air from being too dry.

4. You can lower the temperature appropriately at night and use sleep mode to save energy.

5. When not in use for a long time, it is recommended to start and run the system once a month to prevent the system from freezing.

Through the above analysis and suggestions, we hope to help you solve the problem of central air conditioning not heating. If the problem still cannot be solved, it is recommended to contact professional maintenance personnel in time to avoid further damage caused by self-disassembly.

Next article
  • What is LED strobeLED stroboscopic refers to the visible or invisible flickering phenomenon produced by the LED light source during rapid switching. This phenomenon is usually caused by improper power drive method, dimming technology or circuit design, and may have a potential impact on visual health. The following is a detailed analysis of LED strobe:1. Causes of LED flickerLED strobe is mainly related to the follow
    2026-01-25 mechanical
  • What kind of cable is KVVPR?In the fields of electrical engineering and automation control, cable selection is crucial. As a special control cable, KVVPR cable is widely used in industrial environments. This article will introduce the definition, structure, characteristics and application scenarios of KVVPR cable in detail, and attach relevant data tables so that readers can understand its performance parameters more
    2026-01-22 mechanical
  • What are the thread specifications?Thread specifications are standardized parameters commonly used in machine manufacturing and engineering design to describe the size, shape and performance of threads. Threads are widely used in bolts, nuts, pipe connections and other fields, and the standardization of their specifications ensures the interchangeability and reliability of parts. This article will combine the hot top
    2026-01-20 mechanical
  • What is sensor open circuitSensor open circuit refers to the phenomenon that the signal cannot be transmitted normally due to disconnection of the circuit, poor contact or other reasons under normal working conditions. This phenomenon will directly affect the measurement accuracy and system stability of the sensor, and is one of the common faults in industrial automation, electronic equipment and other fields.This ar
    2026-01-18 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line